Most clear aligners are made in a chain that starts digital and ends physical. The patient’s scan or impression becomes a digital model, a digital setup stages the tooth movement, a model is printed for each stage, a heated sheet of clear thermoplastic is formed over each model, and the aligner is trimmed, finished and checked. Printing the aligner itself directly, without models, is an emerging alternative.
Key takeaways
- Thermoforming over printed models is widely adopted, commercially and clinically, including for in-house production, according to a 2023 review of aligner materials.
- Small errors can add up along the chain, from the scan to thermoforming.
- Material and thickness influence the force an aligner delivers, and thermoforming thins the sheet.
- Materials have moved from single-layer plastics to multilayer sheets, often with a hard and a soft layer.
- Directly printed aligners look promising, but a 2026 systematic review of nine studies found the evidence mainly laboratory-based.
What a clear aligner lab does
The American Association of Orthodontists (AAO) notes that clear aligners are not usually fabricated on site: a dental lab or manufacturer turns the clinician’s records and approved plan into a series of appliances. In-house production is an emerging alternative, compared in in-office vs lab aligners. The clinical decisions stay with you: UK guidance from the British Orthodontic Society (BOS) places responsibility for decisions based on diagnostic information from other sources solely on the prescribing clinician.
The production chain at a glance
| Step | What happens | Why it matters |
|---|---|---|
| 1. Records | Intraoral scan, or an impression that is then scanned | Every aligner is built on it |
| 2. Digital setup | Crowns segmented and moved in stages | You approve it before production |
| 3. Stage models | One model per stage, mostly 3D printed | Model accuracy carries into the aligner |
| 4. Thermoforming | Heated sheet formed by vacuum or pressure | The sheet thins and its properties change |
| 5. Trimming and finishing | Removed, trimmed, polished, cleaned | The trim line can affect force |
| 6. Attachment template | Transfer tray made over a model | Rigid templates are recommended |
| 7. Checks | Accuracy and fit | The final check is fit in the mouth |
1. Records and the digital setup
Aligners start from impressions or digital scans (AAO), and BOS notes that an accurate impression is used to create the customised aligners. The 2023 review describes a direct route (an intraoral scanner) and an indirect one (a high-quality polyvinyl siloxane (PVS) impression that is then scanned).
In the planning software, algorithms segment each clinical crown; the teeth are then moved in steps, producing a virtual model per stage; roots can be added from computed tomography (CT) data. The setup details which tooth moves where and in what order. With American Aligners, an orthodontist designs the plan and you approve it; see digital treatment planning and 3D scanning.
2. A printed model for each stage
Each virtual stage becomes a physical model, by milling or, now mostly, 3D printing, which the 2023 review calls the mainstream technology for orthodontic models. Accuracy matters here: in a 2024 laboratory study, hollow printed models with 0.5 mm walls failed to withstand thermoforming in 4 of the 10 trials, while 2.0 mm hollow models and solid models produced clinically acceptable aligners.
3. Thermoforming the sheet
Thermoforming means heating a thermoplastic sheet until it is soft and pliable, forming it over a mould such as a printed model, usually by vacuum or pressure, and letting it cool to keep its shape. It changes the material: a 2021 review notes that forming alters its properties and the mouth modifies them further, and a 2025 review of aligner thermoplastics reports lower transparency as the surface becomes rougher. In a 2019 clinical study of aligners from 18 patients, forming reduced thickness compared with the original sheet, though occlusal thickness was reproducible. In a 2025 laboratory study, positive-pressure forming reproduced the model more faithfully than vacuum forming.
4. Trimming, finishing and attachment templates
The formed aligners are removed from the models, cut, trimmed, cleaned and sterilised (2025 review), and polished (2023 review). Trim line design matters: in a 2026 laboratory study of 60 PET-G aligners, thickness and trimming pattern both significantly influenced force delivery during arch expansion.
If the plan includes attachments (small tooth-coloured composite shapes bonded to the teeth to help guide them into place), a template is needed to place them. In one 2025 laboratory study the templates were thermoformed on 3D-printed models, and a 2026 scoping review recommends rigid plastic templates for precise placement. Chairside steps: clear aligner attachments and IPR.
5. Checks along the chain
With several steps, small deviations can add up: the 2023 review refers to cumulative errors from the impression, the intraoral scan, the printed model and the thermoforming process. Ask any lab how it checks each step. At the chair, the last check is fit: Cleveland Clinic describes a follow-up to check that the device fits well and is working, and tells patients to call if a tray feels loose or does not fit.
Materials in general terms
The AAO describes aligners as made from smooth, transparent, medical-grade plastic, and the 2025 review names the principal requirement: a transparent and biocompatible plastic. The most common family is PET and its glycol-modified form, PETG, followed by thermoplastic polyurethane (TPU); the 2026 scoping review describes modern aligners as typically PETG or polyurethane-based laminates.
Materials have evolved from single-layer plastics to multilayer sheets that join two or more plastics, often a hard and a soft layer: the soft layer lets the aligner seat smoothly and the hard layer gives strength and durability (2023 review). Composition and thickness influence the force delivered, and that force fades through stress relaxation, which the same review calls presumably the most crucial factor in aligner efficiency. Many formulations are on the market, so ask for the exact material.
Direct-printed aligners: an emerging method
Direct printing skips the models and the sheet: the aligner itself is printed from the digital design. The 2023 review expects it to be the next paradigm shift and notes that, in theory, it allows aligner thickness to vary across the arch. A 2024 review calls post-print processing indispensable for mechanical stability, and the 2021 review urges special care over the cytotoxicity of printable resins.
The 2026 systematic review of nine studies found significant force decay in thermoformed PET-G aligners, particularly in the first 24 to 48 hours of wear, while direct-printed aligners kept more consistent force levels. But the evidence was predominantly laboratory-based and clinical validation remains limited, so direct printing is promising rather than proven.
What to ask a clear aligner lab
- Which material and thickness do you use, single-layer or multilayer, and what biocompatibility documentation can you share?
- Are the aligners thermoformed or printed directly? If printed, how are they cleaned and cured?
- How are the stage models made, and how is their accuracy checked?
- Which trim line do you use, and does it change with the planned movement?
- Do you supply an attachment template, and is it rigid?
- What checks happen before dispatch, and what happens if an aligner does not fit?
- Who designs the setup, and how do I review and approve it before production?
For a wider comparison between companies, see how to choose a clear aligner company; for a case from records to retention, see the clear aligner case workflow.
Frequently asked questions
Are clear aligners still made by hand?
Not commercially. The 2023 review notes that the early manual methods are no longer used for commercial fabrication; today’s method relies on computer-aided design and manufacturing (CAD/CAM) and a digital workflow.
Is a thicker aligner better?
Not necessarily. In the 2026 systematic review, thicknesses between 0.5 and 0.75 mm did not substantially change moment-to-force ratios for specific movements such as palatal tipping, suggesting that material choice outweighs thickness.
Can a clinic make its own aligners?
Yes. Thermoforming is used for in-house production, and the 2026 scoping review calls in-office fabrication an emerging area of practice that bypasses the external laboratory. The 2023 review notes that printing the stage models and thermoforming are time-consuming and labour-intensive; the comparison linked above covers the trade-offs.
Get started with American Aligners
With American Aligners, you upload scans and images, an orthodontist designs the plan, you approve it, and the aligners are delivered. Become a provider or see the workflow on our products.